Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_TemperatureProtection.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: translateModel(Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_TemperatureProtection,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_TemperatureProtection") Notification: Performance of loadModel(Buildings): time 4.023/4.023, allocations: 433.4 MB / 440.9 MB, free: 10.4 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 2.001e-05/2.012e-05, allocations: 4 kB / 0.5325 GB, free: 1.867 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5018/0.5019, allocations: 98.71 MB / 0.6289 GB, free: 15.71 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.9593/1.461, allocations: 406.5 MB / 1.026 GB, free: 7.137 MB / 0.7448 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002555/1.461, allocations: 93.31 kB / 1.026 GB, free: 7.09 MB / 0.7448 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Media/Refrigerants/R410A/specificIsobaricHeatCapacityVap_Tv.mo:42:3-42:35:writable] Error: Variable A not found in scope Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Media/Refrigerants/R410A/isentropicExponentVap_Tv.mo:20:3-20:84:writable] Error: Class Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv not found in scope Buildings.Fluid.HeatPumps.Compressors.ScrollCompressor$heaPum$com.ref.isentropicExponentVap_Tv (looking for a function or record). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_TemperatureProtection Notification: Performance of FrontEnd: time 0.8118/2.273, allocations: 115.6 MB / 1.139 GB, free: 265.1 MB / 0.8073 GB