Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: translateModel(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week") Notification: Performance of loadModel(Buildings): time 3.737/3.737, allocations: 433.3 MB / 440.9 MB, free: 4.578 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 2.147e-05/2.125e-05, allocations: 4.25 kB / 0.5325 GB, free: 12.64 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1665/0.1666, allocations: 98.74 MB / 0.6289 GB, free: 9.168 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.6763/0.8429, allocations: 155.9 MB / 0.7812 GB, free: 58.6 MB / 0.6511 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003292/0.8432, allocations: 110.9 kB / 0.7813 GB, free: 58.6 MB / 0.6511 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/GroundTemperatureResponse.mo:8:3-10:87:writable] Error: Array equation has unknown size in groTemRes.borFieDat.conDat.cooBor=borFieDat.conDat.cooBor. Error: Internal error - InstUtil.moveBindings: Mismatched number of equations and variables. Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week Notification: Performance of FrontEnd: time 0.1993/1.043, allocations: 33.68 MB / 0.8142 GB, free: 56.48 MB / 0.6511 GB