Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: translateModel(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells") Notification: Performance of loadModel(Buildings): time 3.938/3.938, allocations: 433.4 MB / 440.9 MB, free: 10.38 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 2.18e-05/2.189e-05, allocations: 4 kB / 0.5326 GB, free: 1.816 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4941/0.4941, allocations: 98.7 MB / 0.629 GB, free: 15.68 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.1913/0.6854, allocations: 124.6 MB / 0.7507 GB, free: 2.883 MB / 0.6198 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003412/0.6858, allocations: 111.8 kB / 0.7508 GB, free: 2.773 MB / 0.6198 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/LoadAggregation/Validation/ShiftAggregationCells.mo:15:5-20:21:writable] Error: Type mismatch for named argument in Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.shiftAggregationCells(rCel={1, 1, 1, 2, 2}). The argument has type: Integer[5] expected type: Real[i] Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.LoadAggregation.Validation.ShiftAggregationCells Notification: Performance of FrontEnd: time 0.002696/0.6885, allocations: 0.8226 MB / 0.7516 GB, free: 1.949 MB / 0.6198 GB