Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel") Notification: Performance of loadModel(Buildings): time 3.795/3.795, allocations: 433.3 MB / 440.9 MB, free: 10.47 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 1.887e-05/1.891e-05, allocations: 4 kB / 0.5325 GB, free: 1.949 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4854/0.4855, allocations: 98.71 MB / 0.6289 GB, free: 15.73 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.9699/1.455, allocations: 431.7 MB / 1.051 GB, free: 15.09 MB / 0.7761 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002948/1.456, allocations: 108.9 kB / 1.051 GB, free: 15.03 MB / 0.7761 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Applications/DataCenters/ChillerCooled/Equipment/BaseClasses/PartialPumpParallel.mo:104:11-104:18:writable] Error: Type mismatch in binding hydraulicEfficiency = Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency({0}, {0.7}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[1] V_flow; Real(max = 1.0, quantity = "Efficiency", unit = "1", min = 0.0)[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency Integer[1] V_flow; Real[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel Notification: Performance of FrontEnd: time 1.376/2.832, allocations: 341.2 MB / 1.384 GB, free: 33.31 MB / 0.8073 GB