Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop.conf.json Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop") Notification: Performance of loadModel(Buildings): time 3.909/3.909, allocations: 433.4 MB / 440.9 MB, free: 10.46 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 1.607e-05/1.612e-05, allocations: 0 / 0.5325 GB, free: 1.941 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4876/0.4876, allocations: 98.71 MB / 0.6289 GB, free: 15.73 MB / 0.5105 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.064/6.552, allocations: 2.556 GB / 3.185 GB, free: 134.4 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000279/6.552, allocations: 111.5 kB / 3.186 GB, free: 134.3 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Applications/DataCenters/ChillerCooled/Equipment/Validation/CoolingCoilHumidifyingHeating_ClosedLoop.mo:9:22-9:46:writable] Error: Class Medium2 not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra.Medium. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sensors/MassFractionTwoPort.mo:27:11-27:55:writable] Error: Variable Medium.substanceNames[1:Medium.nXi] not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Applications/DataCenters/ChillerCooled/Equipment/Validation/CoolingCoilHumidifyingHeating_ClosedLoop.mo:9:22-9:46:writable] Error: Class Medium2 not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra.Medium. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork@2/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sensors/MassFractionTwoPort.mo:26:3-28:103:writable] Error: Class Medium.MassFraction not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra while instantiating masFra.XiVec. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop Notification: Performance of FrontEnd: time 1.459/8.012, allocations: 363.8 MB / 3.541 GB, free: 93.46 MB / 0.823 GB