Running command: translateModel(Buildings.Experimental.DistrictHeatingCooling.SubStations.VaporCompression.Validation.HeatingCoolingHotwaterTimeSeries_dT,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_5.0.1_Buildings.Experimental.DistrictHeatingCooling.SubStations.VaporCompression.Validation.HeatingCoolingHotwaterTimeSeries_dT") Notification: Performance of loadModel(Buildings): time 3.652/3.652, allocations: 403.9 MB / 411 MB, free: 392 kB / 314.7 MB Notification: Performance of FrontEnd - loaded program: time 1.749e-05/1.758e-05, allocations: 0 / 0.4942 GB, free: 1.371 MB / 410.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4749/0.4749, allocations: 92.69 MB / 0.5847 GB, free: 2.348 MB / 474.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 6.136/6.611, allocations: 2.5 GB / 3.085 GB, free: 0.6289 MB / 0.7761 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000279/6.611, allocations: 101.1 kB / 3.085 GB, free: 0.5742 MB / 0.7761 GB [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2346:7-2347:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$subSta$loa.getDerTableValue. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2312:7-2313:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$subSta$loa.getTableValue. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2358:7-2359:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$subSta$loa.getTableTimeTmin. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Blocks/Sources.mo:2369:7-2370:66:writable] Warning: Unused input variable tableAvailable in function .Modelica.Blocks.Sources.CombiTimeTable$subSta$loa.getTableTimeTmax. [/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 5.0.1/Experimental/DistrictHeatingCooling/SubStations/VaporCompression/HeatingCoolingHotwaterTimeSeries_dT.mo:235:3-247:75:writable] Error: Variable subSta.chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$subSta$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Experimental.DistrictHeatingCooling.SubStations.VaporCompression.Validation.HeatingCoolingHotwaterTimeSeries_dT Notification: Performance of FrontEnd: time 1.082/7.693, allocations: 210.6 MB / 3.291 GB, free: 109.7 MB / 0.7761 GB