Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_3.0.0_Buildings.Rooms.BaseClasses.Examples.RadiationTemperature.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo", uses=false) Using package Modelica_StateGraph2 with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo) Using package ModelicaServices with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo) Using package Modelica with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo) Using package Complex with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo) Using package Buildings with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo) Running command: translateModel(Buildings.Rooms.BaseClasses.Examples.RadiationTemperature,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.Rooms.BaseClasses.Examples.RadiationTemperature") translateModel(Buildings.Rooms.BaseClasses.Examples.RadiationTemperature,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.Rooms.BaseClasses.Examples.RadiationTemperature") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo): time 0.8753/0.8753, allocations: 132.4 MB / 139.9 MB, free: 2.805 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo): time 0.0009906/0.0009906, allocations: 171.8 kB / 171.8 MB, free: 4.938 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo): time 1.295/1.295, allocations: 170.6 MB / 374.2 MB, free: 176 kB / 282.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo): time 0.001678/0.001678, allocations: 117.8 kB / 444.8 MB, free: 14.15 MB / 314.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:257:38-257:110:writable] Warning: The file was not encoded in UTF-8: "

An important practical aspect of state machines is the abilit...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:761:36-761:108:writable] Warning: The file was not encoded in UTF-8: "

The Modelica_StateGraph2 library is described in detail in (O...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:1435:36-1435:108:writable] Warning: The file was not encoded in UTF-8: "

Main Authors:
SCode: time 0.1462/0.1462, allocations: 73.41 MB / 0.6666 GB, free: 15.64 MB / 410.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.5003/0.6465, allocations: 118.1 MB / 0.7819 GB, free: 13.52 MB / 490.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003465/0.6469, allocations: 83.95 kB / 0.782 GB, free: 13.44 MB / 490.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/Rooms/BaseClasses/Examples/RadiationTemperature.mo:20:11-20:36:writable] Error: Type mismatch in binding ove = Buildings.Rooms.BaseClasses.Overhang$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.Rooms.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.Rooms.BaseClasses.Overhang;, got type record Buildings.Rooms.BaseClasses.Overhang$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.Rooms.BaseClasses.Overhang$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.Rooms.BaseClasses.Examples.RadiationTemperature Notification: Performance of FrontEnd: time 0.1336/0.7806, allocations: 49.59 MB / 0.8304 GB, free: 11.59 MB / 0.5261 GB