Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_3.0.0_Buildings.Examples.ChillerPlant.DataCenterDiscreteTimeControl.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo", uses=false) Using package Modelica_StateGraph2 with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo) Using package ModelicaServices with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo) Using package Modelica with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo) Using package Complex with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo) Using package Buildings with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo) Running command: translateModel(Buildings.Examples.ChillerPlant.DataCenterDiscreteTimeControl,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.Examples.ChillerPlant.DataCenterDiscreteTimeControl") translateModel(Buildings.Examples.ChillerPlant.DataCenterDiscreteTimeControl,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.Examples.ChillerPlant.DataCenterDiscreteTimeControl") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo): time 0.8624/0.8624, allocations: 132.4 MB / 139.9 MB, free: 2.863 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo): time 0.00165/0.00165, allocations: 180 kB / 171.8 MB, free: 4.949 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo): time 1.482/1.482, allocations: 170.6 MB / 374.2 MB, free: 184 kB / 282.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo): time 0.001825/0.001825, allocations: 108.1 kB / 444.8 MB, free: 14.16 MB / 314.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:257:38-257:110:writable] Warning: The file was not encoded in UTF-8: "

An important practical aspect of state machines is the abilit...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:761:36-761:108:writable] Warning: The file was not encoded in UTF-8: "

The Modelica_StateGraph2 library is described in detail in (O...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:1435:36-1435:108:writable] Warning: The file was not encoded in UTF-8: "

Main Authors:
SCode: time 0.1649/0.165, allocations: 73.41 MB / 0.6666 GB, free: 15.67 MB / 410.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 7.054/7.219, allocations: 2.482 GB / 3.149 GB, free: 168 MB / 0.6198 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002853/7.22, allocations: 84.06 kB / 3.149 GB, free: 168 MB / 0.6198 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:12160:5-12166:3:writable] Warning: Usage of non-standard operator (not specified in the Modelica specification): Connections.uniqueRoot. Functionality might be partially supported but is not guaranteed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/Fluid/HeatExchangers/DryCoilCounterFlow.mo:109:5-109:77:writable] Error: Component cooCoi.ele[4].initialize_p1 of variability CONST has binding false of higher variability PARAM. Error: Error occurred while flattening model Buildings.Examples.ChillerPlant.DataCenterDiscreteTimeControl Notification: Performance of FrontEnd: time 4.323/11.54, allocations: 1.082 GB / 4.231 GB, free: 50.15 MB / 0.6511 GB