Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildSysPro_BuildSysPro.Systems.HVAC.Emission.ElectricHeater.JouleHeatingPIControlled.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package BuildSysPro with version 3.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo) Running command: translateModel(BuildSysPro.Systems.HVAC.Emission.ElectricHeater.JouleHeatingPIControlled,tolerance=1e-06,outputFormat="empty",numberOfIntervals=900,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.HVAC.Emission.ElectricHeater.JouleHeatingPIControlled") translateModel(BuildSysPro.Systems.HVAC.Emission.ElectricHeater.JouleHeatingPIControlled,tolerance=1e-06,outputFormat="empty",numberOfIntervals=900,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.HVAC.Emission.ElectricHeater.JouleHeatingPIControlled") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo): time 0.7449/0.7449, allocations: 127.4 MB / 134.9 MB, free: 3.734 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001022/0.001022, allocations: 180.9 kB / 164.7 MB, free: 6.527 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.68/1.68, allocations: 205.2 MB / 399.5 MB, free: 5.867 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008596/0.0008597, allocations: 95.44 kB / 476.7 MB, free: 8.598 MB / 378.7 MB Notification: Performance of FrontEnd - loaded program: time 1.81e-05/1.811e-05, allocations: 4 kB / 0.5466 GB, free: 60.5 MB / 394.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1655/0.1655, allocations: 76.75 MB / 0.6215 GB, free: 15.68 MB / 426.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo:2:1-8495:13:writable] Error: Class Units.SI.Power not found in scope Modelica. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/Systems/HVAC/Emission/ElectricHeater/JouleHeatingPIControlled.mo:4:3-13:28:writable] Error: Class Modelica.Units.SI.Power not found in scope BuildSysPro.Systems.HVAC.Emission.ElectricHeater.JouleHeatingPIControlled. Error: Error occurred while flattening model BuildSysPro.Systems.HVAC.Emission.ElectricHeater.JouleHeatingPIControlled Notification: Performance of FrontEnd: time 0.4927/0.6583, allocations: 100.3 MB / 0.7195 GB, free: 14.9 MB / 490.7 MB