Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildSysPro_BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package BuildSysPro with version 3.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo) Running command: translateModel(BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater,tolerance=1e-06,outputFormat="empty",numberOfIntervals=480,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater") translateModel(BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater,tolerance=1e-06,outputFormat="empty",numberOfIntervals=480,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo): time 0.6804/0.6804, allocations: 127.4 MB / 134.9 MB, free: 3.734 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001007/0.001007, allocations: 180.8 kB / 164.7 MB, free: 6.539 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.531/1.531, allocations: 205.2 MB / 399.5 MB, free: 5.93 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007941/0.0007941, allocations: 91.5 kB / 476.7 MB, free: 8.656 MB / 378.7 MB Notification: Performance of FrontEnd - loaded program: time 1.657e-05/1.655e-05, allocations: 4 kB / 0.5466 GB, free: 60.51 MB / 394.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1385/0.1385, allocations: 76.76 MB / 0.6215 GB, free: 15.68 MB / 426.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo:2:1-8495:13:writable] Error: Class Units.SI.Volume not found in scope Modelica. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/Systems/DHW/Electric/ResistiveWaterHeater.mo:4:3-5:38:writable] Error: Class Modelica.Units.SI.Volume not found in scope BuildSysPro.Systems.DHW.Electric.ResistiveWaterHeater. Error: Error occurred while flattening model BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater Notification: Performance of FrontEnd: time 0.4876/0.6262, allocations: 100.5 MB / 0.7197 GB, free: 14.71 MB / 490.7 MB