Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildSysPro_BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package BuildSysPro with version 3.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo) Running command: translateModel(BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater,tolerance=1e-06,outputFormat="empty",numberOfIntervals=480,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater") translateModel(BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater,tolerance=1e-06,outputFormat="empty",numberOfIntervals=480,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo): time 0.7359/0.7359, allocations: 127.4 MB / 134.9 MB, free: 3.477 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001052/0.001052, allocations: 183.4 kB / 164.7 MB, free: 11.61 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.364/1.364, allocations: 205.2 MB / 399.5 MB, free: 13.49 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007609/0.000761, allocations: 93.41 kB / 476.7 MB, free: 1.457 MB / 362.7 MB Notification: Performance of FrontEnd - loaded program: time 1.306e-05/1.308e-05, allocations: 2.5 kB / 0.5466 GB, free: 95.58 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1494/0.1494, allocations: 76.76 MB / 0.6215 GB, free: 43.09 MB / 442.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo:2:1-8495:13:writable] Error: Class Units.SI.Volume not found in scope Modelica. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/Systems/DHW/Electric/ResistiveWaterHeater.mo:4:3-5:38:writable] Error: Class Modelica.Units.SI.Volume not found in scope BuildSysPro.Systems.DHW.Electric.ResistiveWaterHeater. Error: Error occurred while flattening model BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater Notification: Performance of FrontEnd: time 0.1286/0.2781, allocations: 100.2 MB / 0.7194 GB, free: 6.715 MB / 0.4948 GB