Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Annex60_1.0.0_Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_reverseFlow.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo) Using package Modelica with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo) Using package Complex with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo) Using package Annex60 with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo) Running command: translateModel(Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_reverseFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_reverseFlow") translateModel(Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_reverseFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_reverseFlow") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo): time 0.4032/0.4032, allocations: 54.41 MB / 61.89 MB, free: 13.75 MB / 58.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo): time 0.001131/0.001131, allocations: 184.1 kB / 75.61 MB, free: 0.7734 MB / 58.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo): time 1.554/1.554, allocations: 194.3 MB / 283.5 MB, free: 14.86 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo): time 0.001637/0.001637, allocations: 118.2 kB / 341.6 MB, free: 4.047 MB / 250.7 MB Notification: Performance of FrontEnd - loaded program: time 1.67e-05/1.671e-05, allocations: 4 kB / 405.5 MB, free: 4.156 MB / 314.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3984/0.3984, allocations: 57.63 MB / 463.1 MB, free: 51.72 MB / 362.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.7615/1.16, allocations: 360.3 MB / 0.8042 GB, free: 13.62 MB / 0.4948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002915/1.16, allocations: 88.94 kB / 0.8043 GB, free: 13.58 MB / 0.4948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/HeatPumps/Validation/Carnot_TCon_reverseFlow.mo:33:3-47:71:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope Annex60.Fluid.HeatPumps.Carnot_TCon$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_reverseFlow Notification: Performance of FrontEnd: time 0.5714/1.732, allocations: 101.6 MB / 0.9035 GB, free: 126.3 MB / 0.4948 GB