Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Annex60_1.0.0_Annex60.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo) Using package Modelica with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo) Using package Complex with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo) Using package Annex60 with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo) Running command: translateModel(Annex60.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow") translateModel(Annex60.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo): time 0.3402/0.3402, allocations: 54.41 MB / 61.89 MB, free: 13.74 MB / 58.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo): time 0.001211/0.001211, allocations: 187.8 kB / 75.61 MB, free: 0.7617 MB / 58.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo): time 1.541/1.541, allocations: 194.3 MB / 283.5 MB, free: 14.85 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo): time 0.001633/0.001633, allocations: 118.4 kB / 341.6 MB, free: 4.027 MB / 250.7 MB Notification: Performance of FrontEnd - loaded program: time 1.58e-05/1.582e-05, allocations: 4.219 kB / 405.5 MB, free: 4.145 MB / 314.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.396/0.396, allocations: 57.64 MB / 463.1 MB, free: 51.65 MB / 362.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.644/1.04, allocations: 360.3 MB / 0.8042 GB, free: 14.11 MB / 0.4948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002618/1.04, allocations: 83.62 kB / 0.8043 GB, free: 14.07 MB / 0.4948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/Chillers/Validation/Carnot_TEva_reverseFlow.mo:22:3-37:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Annex60.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Annex60.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow Notification: Performance of FrontEnd: time 0.4152/1.456, allocations: 80.38 MB / 0.8828 GB, free: 147.9 MB / 0.4948 GB