Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/../OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr SiemensPower_SiemensPower.Components.Pipes.Tests.tubeTest.conf.json Using package ModelicaServices with version 3.2.1 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.1/package.mo) Using package Complex with version 3.2.1 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Complex 3.2.1.mo) Using package Modelica with version 3.2.1 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/Modelica 3.2.1/package.mo) Using package SiemensPower with version 2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/SiemensPower 2.2/package.mo) Running command: "" <> buildModelFMU(SiemensPower.Components.Pipes.Tests.tubeTest,fileNamePrefix="SiemensPower_SiemensPower_Components_Pipes_Tests_tubeTest",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadModel(SiemensPower): time 1.796/1.796, allocations: 176.9 MB / 184.5 MB, free: 1.027 MB / 154.9 MB Notification: Performance of FrontEnd - loaded program: time 1.93e-05/1.933e-05, allocations: 0 / 230.3 MB, free: 1.5 MB / 186.9 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.08655/0.08661, allocations: 40.04 MB / 270.4 MB, free: 9.375 MB / 234.9 MB Notification: Performance of FrontEnd - scodeFlatten: time 7.913/8, allocations: 2.626 GB / 2.89 GB, free: 11.74 MB / 362.9 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0001713/8, allocations: 55.83 kB / 2.89 GB, free: 11.72 MB / 362.9 MB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/SiemensPower 2.2/Interfaces/portHeat.mo:15:3-15:40:writable] Warning: Ignoring the modification on outer element: SH.heatport.TWall = {SH.TWall[1], SH.TWall[2], SH.TWall[3]}. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/SiemensPower 2.2/Interfaces/portHeat.mo:15:3-15:40:writable] Warning: No corresponding 'inner' declaration found for component .Real SH.heatport.TWall declared as 'outer '. The existing 'inner' components are: There are no 'inner' components defined in the model in any of the parent scopes of 'outer' component's scope: SiemensPower.Interfaces.portHeat$SH$heatport. Check if you have not misspelled the 'outer' component name. Please declare an 'inner' component with the same name in the top scope. Continuing flattening by only considering the 'outer' component declaration. [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OMCompiler/build/lib/omlibrary/SiemensPower 2.2/Components/Pipes/TubeOwnMedia.mo:91:3-101:53:writable] Error: Variable SH.wall: In modifier (init = SH.initOptWall), class or component init not found in . Error: Error occurred while flattening model SiemensPower.Components.Pipes.Tests.tubeTest Notification: Performance of FrontEnd: time 1.278/9.278, allocations: 199.5 MB / 3.085 GB, free: 60.36 MB / 362.9 MB