OMSimulator -r=ScalableTestSuite_ScalableTestSuite.Electrical.BreakerCircuits.ScaledExperiments.BreakerNetwork_N_320_M_10_res.mat --tempDir=temp_ScalableTestSuite_ScalableTestSuite_Electrical_BreakerCircuits_ScaledExperiments_BreakerNetwork_N_320_M_10_fmu --startTime=0 --stopTime=2 --timeout=300 --tolerance=1e-06 ScalableTestSuite_ScalableTestSuite_Electrical_BreakerCircuits_ScaledExperiments_BreakerNetwork_N_320_M_10.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_ScalableTestSuite_ScalableTestSuite_Electrical_BreakerCircuits_ScaledExperiments_BreakerNetwork_N_320_M_10_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ScalableTestSuite_ScalableTestSuite.Electrical.BreakerCircuits.ScaledExperiments.BreakerNetwork_N_320_M_10/temp_ScalableTestSuite_ScalableTestSuite_Electrical_BreakerCircuits_ScaledExperiments_BreakerNetwork_N_320_M_10_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ScalableTestSuite_ScalableTestSuite.Electrical.BreakerCircuits.ScaledExperiments.BreakerNetwork_N_320_M_10" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/ScalableTestSuite_ScalableTestSuite.Electrical.BreakerCircuits.ScaledExperiments.BreakerNetwork_N_320_M_10/temp_ScalableTestSuite_ScalableTestSuite_Electrical_BreakerCircuits_ScaledExperiments_BreakerNetwork_N_320_M_10_fmu/model-91j0z092" stdout | info | Using sparse solver for linear system 0, | | | | because density of 0.003 remains under threshold of 0.200 and size of 962 exceeds threshold of 201. | | | | The maximum density and the minimal system size for using sparse solvers can be specified | | | | using the runtime flags '<-lssMaxDensity=value>' and '<-lssMinSize=value>'. stdout | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. stdout | info | Using sparse solver for linear system 1, | | | | because density of 0.003 remains under threshold of 0.200 and size of 962 exceeds threshold of 201. | | | | The maximum density and the minimal system size for using sparse solvers can be specified | | | | using the runtime flags '<-lssMaxDensity=value>' and '<-lssMinSize=value>'. stdout | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. info: maximum step size for 'model.root': 0.100000 info: No result file will be created stdout | info | Breaker 320 opens at time = 0.424242 stdout | info | Breaker 319 opens at time = 0.424242 stdout | info | Breaker 318 opens at time = 0.424242 stdout | info | Breaker 317 opens at time = 0.424242 stdout | info | Breaker 316 opens at time = 0.424242 stdout | info | Breaker 315 opens at time = 0.424242 stdout | info | Breaker 314 opens at time = 0.424242 stdout | info | Breaker 313 opens at time = 0.424242 stdout | info | Breaker 312 opens at time = 0.424242 stdout | info | Breaker 311 opens at time = 0.424242 info: Final Statistics for 'model.root': NumSteps = 40 NumRhsEvals = 54 NumLinSolvSetups = 12 NumNonlinSolvIters = 53 NumNonlinSolvConvFails = 0 NumErrTestFails = 2