Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_PowerSystems.Examples.Wind.WindTurbine_PSGI.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo", uses=false) Using package PowerSystems with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo) Using package ModelicaServices with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo) Using package Modelica with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo) Using package Complex with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo) Running command: "" <> buildModelFMU(PowerSystems.Examples.Wind.WindTurbine_PSGI,fileNamePrefix="PowerSystems_PowerSystems_Examples_Wind_WindTurbine_PSGI",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(PowerSystems.Examples.Wind.WindTurbine_PSGI,fileNamePrefix="PowerSystems_PowerSystems_Examples_Wind_WindTurbine_PSGI",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo): time 0.001577/0.001576, allocations: 179.1 kB / 8.351 MB, free: 0.7227 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo): time 1.776/1.776, allocations: 194.3 MB / 203.1 MB, free: 12.96 MB / 170.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo): time 0.00158/0.00158, allocations: 120.6 kB / 248.1 MB, free: 15.97 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo): time 0.1898/0.1898, allocations: 37.93 MB / 330.9 MB, free: 2.652 MB / 234.7 MB Notification: Performance of FrontEnd - loaded program: time 1.925e-05/1.927e-05, allocations: 3.938 kB / 390.5 MB, free: 7.012 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3166/0.3167, allocations: 53.22 MB / 443.7 MB, free: 17.75 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.5149/0.8316, allocations: 139.7 MB / 0.5697 GB, free: 29.53 MB / 378.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000209/0.8319, allocations: 89.61 kB / 0.5698 GB, free: 29.52 MB / 378.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/AC3ph/Machines.mo:424:36-424:44:writable] Warning: Non-array modification '"1"' for array component, possibly due to missing 'each'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/AC3ph/Machines.mo:430:36-430:44:writable] Warning: Non-array modification '"1"' for array component, possibly due to missing 'each'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/AC3ph/Machines.mo:2240:3-2240:48:writable] Error: Could not evaluate structural parameter (or constant): n_d which gives dimensions of array: L_rd[n_d]. Array dimensions must be known at compile time. Error: Error occurred while flattening model PowerSystems.Examples.Wind.WindTurbine_PSGI Notification: Performance of FrontEnd: time 0.08803/0.9199, allocations: 35.12 MB / 0.6041 GB, free: 9.074 MB / 378.7 MB