Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.TwoBusesResistiveTransmissionLineFault.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: "" <> buildModelFMU(PowerGrids.Electrical.Test.TwoBusesResistiveTransmissionLineFault,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_TwoBusesResistiveTransmissionLineFault",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(PowerGrids.Electrical.Test.TwoBusesResistiveTransmissionLineFault,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_TwoBusesResistiveTransmissionLineFault",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001181/0.001181, allocations: 180.9 kB / 7.65 MB, free: 1.422 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.87/1.87, allocations: 205.3 MB / 213.4 MB, free: 13.77 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009727/0.0009729, allocations: 89.36 kB / 261.4 MB, free: 13.45 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo): time 0.05926/0.05926, allocations: 14.03 MB / 323.4 MB, free: 15.35 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 2.075e-05/2.077e-05, allocations: 0 / 380.8 MB, free: 73.83 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1254/0.1254, allocations: 51.12 MB / 431.9 MB, free: 22.73 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.4366/0.562, allocations: 84.92 MB / 0.5047 GB, free: 11.27 MB / 330.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002421/0.5623, allocations: 70.91 kB / 0.5048 GB, free: 11.26 MB / 330.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$infiniteBusA$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.TwoBusesResistiveTransmissionLineFault Notification: Performance of FrontEnd: time 0.01239/0.5747, allocations: 5.522 MB / 0.5102 GB, free: 9.199 MB / 330.7 MB