Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.TestTransformerWithTapChangerInterval.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Ignoring simflag -noemit -emit_protected=() since it seems broken on HelloWorld Running command: "" <> buildModelFMU(PowerGrids.Electrical.Test.TestTransformerWithTapChangerInterval,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_TestTransformerWithTapChangerInterval",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(PowerGrids.Electrical.Test.TestTransformerWithTapChangerInterval,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_TestTransformerWithTapChangerInterval",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001073/0.001073, allocations: 172.5 kB / 7.646 MB, free: 1.422 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.815/1.815, allocations: 205.3 MB / 213.4 MB, free: 13.76 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008678/0.0008677, allocations: 87.3 kB / 261.4 MB, free: 13.45 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo): time 0.05797/0.05797, allocations: 14.04 MB / 323.4 MB, free: 15.34 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 2.1e-05/2.089e-05, allocations: 4 kB / 382.4 MB, free: 72.29 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.09037/0.09041, allocations: 51.11 MB / 433.5 MB, free: 21.18 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.4503/0.5408, allocations: 91.08 MB / 0.5123 GB, free: 10.13 MB / 330.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003079/0.5411, allocations: 73.36 kB / 0.5123 GB, free: 10.12 MB / 330.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$infiniteBus$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.TestTransformerWithTapChangerInterval Notification: Performance of FrontEnd: time 0.01314/0.5543, allocations: 5.687 MB / 0.5179 GB, free: 7.859 MB / 330.7 MB