Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.TestTransformerFixedRatio.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: "" <> buildModelFMU(PowerGrids.Electrical.Test.TestTransformerFixedRatio,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_TestTransformerFixedRatio",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(PowerGrids.Electrical.Test.TestTransformerFixedRatio,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_TestTransformerFixedRatio",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001098/0.001098, allocations: 169 kB / 7.646 MB, free: 1.426 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.912/1.912, allocations: 205.3 MB / 213.4 MB, free: 13.7 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008342/0.0008343, allocations: 89.55 kB / 261.4 MB, free: 13.43 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo): time 0.08482/0.08482, allocations: 14.04 MB / 323.4 MB, free: 15.32 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 2.311e-05/2.313e-05, allocations: 0 / 380.8 MB, free: 73.84 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1269/0.127, allocations: 51.12 MB / 431.9 MB, free: 22.73 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.4975/0.6245, allocations: 84.09 MB / 0.5039 GB, free: 11.17 MB / 330.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002924/0.6249, allocations: 72.12 kB / 0.504 GB, free: 11.17 MB / 330.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$infiniteBus$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.TestTransformerFixedRatio Notification: Performance of FrontEnd: time 0.01348/0.6384, allocations: 5.528 MB / 0.5094 GB, free: 9.141 MB / 330.7 MB