Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.LoadImpedancePQ.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: "" <> buildModelFMU(PowerGrids.Electrical.Test.LoadImpedancePQ,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_LoadImpedancePQ",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(PowerGrids.Electrical.Test.LoadImpedancePQ,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_LoadImpedancePQ",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001272/0.001273, allocations: 173.9 kB / 7.648 MB, free: 1.422 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.892/1.892, allocations: 205.3 MB / 213.4 MB, free: 13.76 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008151/0.0008151, allocations: 83.38 kB / 261.4 MB, free: 13.45 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo): time 0.05911/0.05911, allocations: 14.04 MB / 323.4 MB, free: 15.33 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 1.987e-05/1.978e-05, allocations: 4 kB / 380.8 MB, free: 73.83 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1235/0.1236, allocations: 51.11 MB / 431.9 MB, free: 22.73 MB / 298.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.4718/0.5954, allocations: 82.89 MB / 0.5028 GB, free: 10.96 MB / 330.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002513/0.5957, allocations: 71.75 kB / 0.5028 GB, free: 10.96 MB / 330.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$load1$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.LoadImpedancePQ Notification: Performance of FrontEnd: time 0.01134/0.6071, allocations: 5.095 MB / 0.5078 GB, free: 9.402 MB / 330.7 MB