Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Modelica_trunk_Modelica.Electrical.Batteries.Examples.BatteryDischargeCharge.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex trunk/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices trunk/package.mo", uses=false) Using package ModelicaServices with version trunk (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices trunk/package.mo) Using package Modelica with version trunk (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/package.mo) Using package Complex with version trunk (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex trunk/package.mo) Running command: "" <> buildModelFMU(Modelica.Electrical.Batteries.Examples.BatteryDischargeCharge,fileNamePrefix="Modelica_trunk_Modelica_Electrical_Batteries_Examples_BatteryDischargeCharge",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Modelica.Electrical.Batteries.Examples.BatteryDischargeCharge,fileNamePrefix="Modelica_trunk_Modelica_Electrical_Batteries_Examples_BatteryDischargeCharge",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex trunk/package.mo): time 0.001543/0.001543, allocations: 198.8 kB / 8.768 MB, free: 320 kB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/package.mo): time 1.391/1.391, allocations: 225.6 MB / 234.8 MB, free: 3.254 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices trunk/package.mo): time 0.0009093/0.0009091, allocations: 96.66 kB / 286.7 MB, free: 5.227 MB / 234.7 MB Notification: Performance of FrontEnd - loaded program: time 2.329e-05/2.332e-05, allocations: 4 kB / 343.8 MB, free: 8.191 MB / 282.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1145/0.1146, allocations: 51.48 MB / 395.3 MB, free: 4.668 MB / 330.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.3671/0.4817, allocations: 90.17 MB / 485.4 MB, free: 2.801 MB / 346.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002107/0.482, allocations: 84.69 kB / 485.5 MB, free: 2.758 MB / 346.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Electrical/Batteries/ParameterRecords/TransientData/CellData.mo:8:3-11:59:writable] Notification: Moving binding to initial equation section and setting fixed attribute of cellData2.rcData[2].R to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Electrical/Batteries/ParameterRecords/TransientData/CellData.mo:8:3-11:59:writable] Notification: Moving binding to initial equation section and setting fixed attribute of cellData2.rcData[2].C to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Electrical/Batteries/ParameterRecords/TransientData/CellData.mo:8:3-11:59:writable] Notification: Moving binding to initial equation section and setting fixed attribute of cellData2.rcData[1].R to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Electrical/Batteries/ParameterRecords/TransientData/CellData.mo:8:3-11:59:writable] Notification: Moving binding to initial equation section and setting fixed attribute of cellData2.rcData[1].C to false. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica trunk/Electrical/Batteries/Examples/BatteryDischargeCharge.mo:52:5-52:23:writable] Error: Type mismatch in binding cellData = cellData2, expected subtype of record Modelica.Electrical.Batteries.ParameterRecords.TransientData.CellData String CellType; Real(displayUnit = "A.h", quantity = "ElectricCharge", unit = "C") Qnom; Boolean useLinearSOCDependency; Real(min = 0.0, quantity = "ElectricPotential", unit = "V") OCVmax; Real(min = 0.0, start = 0.0, quantity = "ElectricPotential", unit = "V") OCVmin; Real(max = 1.0) SOCmax; Real(min = 0.0) SOCmin; Real[2, 2] OCV_SOC; enumeration(LinearSegments, ContinuousDerivative, ConstantSegments, MonotoneContinuousDerivative1, MonotoneContinuousDerivative2, ModifiedContinuousDerivative) smoothness; Real[2, 2] OCV_SOC_internal; Real(quantity = "Resistance", unit = "Ohm") Ri; Real(quantity = "ThermodynamicTemperature", unit = "K", min = 0.0, start = 288.15, nominal = 300.0, displayUnit = "degC") T_ref; Real(quantity = "LinearTemperatureCoefficient", unit = "1/K") alpha; Real(quantity = "ElectricCurrent", unit = "A") Idis; Real(quantity = "Resistance", unit = "Ohm") R0; Integer nRC; record Modelica.Electrical.Batteries.ParameterRecords.TransientData.RCData String CellType; Real(quantity = "Resistance", unit = "Ohm") R; Real(quantity = "ThermodynamicTemperature", unit = "K", min = 0.0, start = 288.15, nominal = 300.0, displayUnit = "degC") T_ref; Real(quantity = "LinearTemperatureCoefficient", unit = "1/K") alpha; Real(quantity = "Capacitance", unit = "F", min = 0.0) C; end Modelica.Electrical.Batteries.ParameterRecords.TransientData.RCData;[1] rcData; end Modelica.Electrical.Batteries.ParameterRecords.TransientData.CellData;, got type record Modelica.Electrical.Batteries.ParameterRecords.TransientData.ExampleData$cellData2 String CellType; Real(displayUnit = "A.h", quantity = "ElectricCharge", unit = "C") Qnom; Boolean useLinearSOCDependency; Real(min = 0.0, quantity = "ElectricPotential", unit = "V") OCVmax; Real(min = 0.0, start = 0.0, quantity = "ElectricPotential", unit = "V") OCVmin; Real(max = 1.0) SOCmax; Real(min = 0.0) SOCmin; Real[29, 2] OCV_SOC; enumeration(LinearSegments, ContinuousDerivative, ConstantSegments, MonotoneContinuousDerivative1, MonotoneContinuousDerivative2, ModifiedContinuousDerivative) smoothness; Real[29, 2] OCV_SOC_internal; Real(quantity = "Resistance", unit = "Ohm") Ri; Real(quantity = "ThermodynamicTemperature", unit = "K", min = 0.0, start = 288.15, nominal = 300.0, displayUnit = "degC") T_ref; Real(quantity = "LinearTemperatureCoefficient", unit = "1/K") alpha; Real(quantity = "ElectricCurrent", unit = "A") Idis; Real(quantity = "Resistance", unit = "Ohm") R0; Integer nRC; record Modelica.Electrical.Batteries.ParameterRecords.TransientData.RCData String CellType; Real(quantity = "Resistance", unit = "Ohm") R; Real(quantity = "ThermodynamicTemperature", unit = "K", min = 0.0, start = 288.15, nominal = 300.0, displayUnit = "degC") T_ref; Real(quantity = "LinearTemperatureCoefficient", unit = "1/K") alpha; Real(quantity = "Capacitance", unit = "F", min = 0.0) C; end Modelica.Electrical.Batteries.ParameterRecords.TransientData.RCData;[2] rcData; end Modelica.Electrical.Batteries.ParameterRecords.TransientData.ExampleData$cellData2;. Error: Error occurred while flattening model Modelica.Electrical.Batteries.Examples.BatteryDischargeCharge Notification: Performance of FrontEnd: time 0.0703/0.5523, allocations: 27.27 MB / 0.5008 GB, free: 11.8 MB / 378.7 MB