OMSimulator -r=ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve_res.mat --tempDir=temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestComponents_Machines_TestWaterPumpCheckValve_fmu --startTime=0 --stopTime=3 --timeout=50 --tolerance=1e-06 ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestComponents_Machines_TestWaterPumpCheckValve.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestComponents_Machines_TestWaterPumpCheckValve_fmu" info: Set temp directory to "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestComponents_Machines_TestWaterPumpCheckValve_fmu" info: Set working directory to "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve" info: New model "model" with corresponding temp directory "/var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestComponents_Machines_TestWaterPumpCheckValve_fmu/model-q7rffkx8" warning: fmu (logStatusWarning): /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Fluid/Machines.mo:317: The following assertion has been violated at time 0.000000 pump.delta_head_init >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= pump.delta_head_init, has value: -50.1499 error: [fmi2logger] fmu (logStatusError): /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/Media/Water/IF97_Utilities.mo:2897: IF97 medium function tsat called with too low pressure p = -410596 Pa <= 611.657 Pa (triple point pressure) error: [fmi2logger] fmu (logFmi2Call): fmi2EnterInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.fmu" Limited backtrace at point of segmentation fault /lib/x86_64-linux-gnu/libpthread.so.0(+0x12890)[0x7fe52a9be890] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libSimulationRuntimeC.so(freeHomotopyData+0x4)[0x7fe52511d4b4] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelica/OMCompiler/build/lib/x86_64-linux-gnu/omc/libSimulationRuntimeC.so(freeNonlinearSystems+0x155)[0x7fe525117565] /var/lib/hudson/slave/workspace/OpenModelica_TEST_LIBS/OpenModelicaLibraryTesting/ModelicaTest_3.2.2_cs_ModelicaTest.Fluid.TestComponents.Machines.TestWaterPumpCheckValve/temp_ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestComponents_Machines_TestWaterPumpCheckValve_fmu/model-q7rffkx8/temp/fmu/binaries/linux64/ModelicaTest_3_2_2_cs_ModelicaTest_Fluid_TestComponents_Machines_TestWaterPumpCheckValve.so(fmi2FreeInstance+0x85)[0x7fe5255eb229] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(+0x1e6e75)[0x55ee91c6ee75] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms14ComponentFMUCS9terminateEv+0x11f)[0x55ee91bbe3ef] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms8SystemWC9terminateEv+0x632)[0x55ee91b841b2] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms5Model9terminateEv+0x4d)[0x55ee91be9e3d] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms5Model10initializeEv+0x500)[0x55ee91beb5a0] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(oms_initialize+0x51)[0x55ee91b2ce91] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(+0xa5b10)[0x55ee91b2db10] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(oms_RunFile+0xae4)[0x55ee91b40544] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms5Flags8FilenameERKNSt7__cxx1112basic_stringIcSt11char_traitsIcESaIcEEE+0xc)[0x55ee91be040c] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(_ZN3oms5Flags20SetCommandLineOptionERKNSt7__cxx1112basic_stringIcSt11char_traitsIcESaIcEEE+0x530)[0x55ee91be3980] /var/lib/hudson/saved_omc/OMSimulator/install/linux/bin/OMSimulator(oms_setCommandLineOption+0x6c)[0x55ee91b2caac]