OMSimulator --tempDir=temp_IDEAS_dev_IDEAS_Fluid_Movers_Validation_Pump_Nrpm_stratos_fmu --startTime=0 --stopTime=1000 --timeout=50 --tolerance=1e-08 IDEAS_dev_IDEAS_Fluid_Movers_Validation_Pump_Nrpm_stratos.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_IDEAS_dev_IDEAS_Fluid_Movers_Validation_Pump_Nrpm_stratos_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_dev_IDEAS.Fluid.Movers.Validation.Pump_Nrpm_stratos/temp_IDEAS_dev_IDEAS_Fluid_Movers_Validation_Pump_Nrpm_stratos_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_dev_IDEAS.Fluid.Movers.Validation.Pump_Nrpm_stratos" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_dev_IDEAS.Fluid.Movers.Validation.Pump_Nrpm_stratos/temp_IDEAS_dev_IDEAS_Fluid_Movers_Validation_Pump_Nrpm_stratos_fmu/model-nc4j9zu1" warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348: The following assertion has been violated during initialization at time 0.000000 forcedPump1.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348: The following assertion has been violated during initialization at time 0.000000 forcedPump2.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348: The following assertion has been violated during initialization at time 0.000000 forcedPump3.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348: The following assertion has been violated during initialization at time 0.000000 forcedPump4.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348: The following assertion has been violated during initialization at time 0.000000 forcedPump5.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. info: maximum step size for 'model.root': 0.100000 info: Result file: model_res.mat (bufferSize=10) info: Final Statistics for 'model.root': NumSteps = 911 NumRhsEvals = 912 NumLinSolvSetups = 48 NumNonlinSolvIters = 911 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 5 warnings info: 0 errors