Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr IDEAS_dev_IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package IDEAS with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years,fileNamePrefix="IDEAS_dev_IDEAS_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_Validation_Analytic_20Years",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years,fileNamePrefix="IDEAS_dev_IDEAS_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_Validation_Analytic_20Years",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001318/0.001318, allocations: 173.9 kB / 7.648 MB, free: 1.422 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/package.mo): time 0.7622/0.7622, allocations: 133.6 MB / 141.6 MB, free: 2.879 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.429/1.429, allocations: 221.5 MB / 395.4 MB, free: 10.78 MB / 330.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008385/0.0008385, allocations: 103 kB / 478.2 MB, free: 1.309 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 2.603e-05/2.636e-05, allocations: 4 kB / 0.5536 GB, free: 8.934 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4102/0.4102, allocations: 82.3 MB / 0.634 GB, free: 40.77 MB / 458.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.1722/0.5825, allocations: 141.9 MB / 0.7725 GB, free: 12.73 MB / 0.5573 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002713/0.5828, allocations: 103.9 kB / 0.7726 GB, free: 12.63 MB / 0.5573 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/GroundTemperatureResponse.mo:8:3-10:87:writable] Error: Array equation has unknown size in groTemRes.borFieDat.conDat.cooBor=borFieDat.conDat.cooBor. Error: Internal error - InstUtil.moveBindings: Mismatched number of equations and variables. Error: Error occurred while flattening model IDEAS.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years Notification: Performance of FrontEnd: time 0.03309/0.6159, allocations: 11.58 MB / 0.7839 GB, free: 1.039 MB / 0.5573 GB