OMSimulator --tempDir=temp_IDEAS_dev_IDEAS_Fluid_Actuators_Valves_Simplified_Examples_Thermostatic3WayValve_fmu --startTime=0 --stopTime=15 --timeout=50 --tolerance=1e-06 IDEAS_dev_IDEAS_Fluid_Actuators_Valves_Simplified_Examples_Thermostatic3WayValve.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_IDEAS_dev_IDEAS_Fluid_Actuators_Valves_Simplified_Examples_Thermostatic3WayValve_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_dev_IDEAS.Fluid.Actuators.Valves.Simplified.Examples.Thermostatic3WayValve/temp_IDEAS_dev_IDEAS_Fluid_Actuators_Valves_Simplified_Examples_Thermostatic3WayValve_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_dev_IDEAS.Fluid.Actuators.Valves.Simplified.Examples.Thermostatic3WayValve" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_dev_IDEAS.Fluid.Actuators.Valves.Simplified.Examples.Thermostatic3WayValve/temp_IDEAS_dev_IDEAS_Fluid_Actuators_Valves_Simplified_Examples_Thermostatic3WayValve_fmu/model-1604ighp" stdout | info | | | | | Warning: | | | | ======== | | | | It is recommended that the volume flow rate versus pressure relation | | | | of the fan or pump satisfies the minimum decrease condition | | | | | | | | (per.pressure.dp[i+1]-per.pressure.dp[i]) | | | | d[i] = ------------------------------------------------- < -0 | | | | (per.pressure.V_flow[i+1]-per.pressure.V_flow[i]) | | | | | | | | is | | | | d[1]=0 | | | | | | | | Otherwise, a solution to the equations may not exist if the fan or pump speed is reduced. | | | | In this situation, the solver will fail due to non-convergence and | | | | the simulation stops. warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348: The following assertion has been violated during initialization at time 0.000000 pump.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. info: maximum step size for 'model.root': 0.100000 info: Result file: model_res.mat (bufferSize=10) info: Final Statistics for 'model.root': NumSteps = 53 NumRhsEvals = 58 NumLinSolvSetups = 8 NumNonlinSolvIters = 57 NumNonlinSolvConvFails = 0 NumErrTestFails = 1 info: 1 warnings info: 0 errors