Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr IBPSA_latest_IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package IBPSA with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years,fileNamePrefix="IBPSA_latest_IBPSA_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_Validation_Analytic_20Years",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years,fileNamePrefix="IBPSA_latest_IBPSA_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_Validation_Analytic_20Years",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.0009742/0.0009743, allocations: 177.6 kB / 8.005 MB, free: 1.07 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/package.mo): time 0.49/0.49, allocations: 90.92 MB / 99.35 MB, free: 2.176 MB / 74.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.47/1.47, allocations: 221.5 MB / 343.2 MB, free: 1.602 MB / 266.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.00102/0.00102, allocations: 95.89 kB / 415.9 MB, free: 11.16 MB / 346.7 MB Notification: Performance of FrontEnd - loaded program: time 2.269e-05/2.283e-05, allocations: 4 kB / 494.6 MB, free: 52.29 MB / 362.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.141/0.141, allocations: 72.31 MB / 0.5536 GB, free: 12.16 MB / 394.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.5131/0.6542, allocations: 140.4 MB / 0.6908 GB, free: 1.961 MB / 490.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000307/0.6545, allocations: 109 kB / 0.6909 GB, free: 1.898 MB / 490.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IBPSA 4.0.0-master/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/GroundTemperatureResponse.mo:11:3-13:87:writable] Error: Array equation has unknown size in groTemRes.borFieDat.conDat.cooBor=borFieDat.conDat.cooBor. Error: Internal error - InstUtil.moveBindings: Mismatched number of equations and variables. Error: Error occurred while flattening model IBPSA.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.Analytic_20Years Notification: Performance of FrontEnd: time 0.03216/0.6867, allocations: 11.59 MB / 0.7022 GB, free: 8.625 MB / 0.4948 GB