Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr FastBuildings_FastBuildings.Examples.TwoZone_ArtificialInputs.conf.json Using package ModelicaServices with version 1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.1.0/package.mo) Using package Modelica with version 3.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/package.mo) Using package FastBuildings with version 0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/FastBuildings master/package.mo) Using package Complex with version 1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 1.1.0/package.mo) Running command: "" <> buildModelFMU(FastBuildings.Examples.TwoZone_ArtificialInputs,fileNamePrefix="FastBuildings_FastBuildings_Examples_TwoZone_ArtificialInputs",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 1.1.0/package.mo): time 0.001687/0.001687, allocations: 143.6 kB / 7.616 MB, free: 1.453 MB / 5.871 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/FastBuildings master/package.mo): time 0.03464/0.03464, allocations: 4.547 MB / 12.59 MB, free: 320 kB / 7.832 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Fluid/Dissipation.mo:8490:35-8490:107:writable] Warning: The file was not encoded in UTF-8: "

Calculation of a generic pressure loss in dependence of nom...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Fluid/Dissipation.mo:8600:35-8600:107:writable] Warning: The file was not encoded in UTF-8: "

Calculation of a generic pressure loss in dependence of nomi...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Fluid/Dissipation.mo:8738:35-8738:107:writable] Warning: The file was not encoded in UTF-8: "

Calculation of a generic pressure loss in dependence of a pr...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Fluid/Dissipation.mo:8793:35-8793:107:writable] Warning: The file was not encoded in UTF-8: "

Calculation of a generic pressure loss with linear or quadra...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:570:14-570:31:writable] Warning: Treating .0158271919734802 as 0.0158271919734802. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:570:48-570:65:writable] Warning: Treating .0942738402188500 as 0.0942738402188500. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:571:13-571:29:writable] Warning: Treating .155071987336585 as 0.155071987336585. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:571:47-571:63:writable] Warning: Treating .188821573960182 as 0.188821573960182. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:572:9-572:25:writable] Warning: Treating .199773405226859 as 0.199773405226859. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:572:42-572:58:writable] Warning: Treating .224926465333340 as 0.224926465333340. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:572:75-572:91:writable] Warning: Treating .242611071901408 as 0.242611071901408. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/package.mo): time 1.506/1.506, allocations: 150.6 MB / 164.7 MB, free: 5.594 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.1.0/package.mo): time 0.001675/0.001675, allocations: 78.16 kB / 200.7 MB, free: 1.496 MB / 170.7 MB Notification: Performance of FrontEnd - loaded program: time 1.969e-05/1.983e-05, allocations: 224 / 242.6 MB, free: 6.203 MB / 170.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1037/0.1038, allocations: 35.59 MB / 278.2 MB, free: 2.535 MB / 202.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.3415/0.4453, allocations: 47.72 MB / 325.9 MB, free: 4.203 MB / 234.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0001525/0.4455, allocations: 47.98 kB / 326 MB, free: 4.156 MB / 234.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/FastBuildings master/Zones/BaseClasses/Partials/Partial_SZ_ZonWal.mo:37:3-40:27:writable] Error: The type of variables simFasBui.TAmb type: Real and bui.zon1.preTAmb.T type: Real are inconsistent in connect equations. Notification: Performance of FrontEnd - DAE generated: time 0.04754/0.4931, allocations: 11.72 MB / 337.7 MB, free: 8.375 MB / 250.7 MB Notification: Performance of FrontEnd: time 1.794e-06/0.4931, allocations: 4 kB / 337.7 MB, free: 8.371 MB / 250.7 MB Notification: Performance of Transformations before backend: time 3.286e-05/0.4932, allocations: 12 kB / 337.7 MB, free: 8.359 MB / 250.7 MB Error: Too few equations, under-determined system. The model has 120 equation(s) and 121 variable(s).