Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case650FF",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case650FF",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.758/1.758, allocations: 285.6 MB / 293.1 MB, free: 10.22 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001592/0.001592, allocations: 172.9 kB / 361.4 MB, free: 6.836 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.104/2.104, allocations: 205.2 MB / 0.62 GB, free: 11.64 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001004/0.001004, allocations: 92.59 kB / 0.733 GB, free: 44.15 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 3.072e-05/3.081e-05, allocations: 4 kB / 0.8518 GB, free: 2.609 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8288/0.8289, allocations: 115.3 MB / 0.9645 GB, free: 78.67 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.117/7.946, allocations: 2.244 GB / 3.209 GB, free: 283.2 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004201/7.947, allocations: 117 kB / 3.209 GB, free: 283.1 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF Notification: Performance of FrontEnd: time 2.053/10, allocations: 0.5157 GB / 3.725 GB, free: 120.7 MB / 0.948 GB