Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimaryLoadSideEconomizer.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimaryLoadSideEconomizer,fileNamePrefix="Buildings_maint_8_0_x_Buildings_Applications_DataCenters_ChillerCooled_Examples_IntegratedPrimaryLoadSideEconomizer",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimaryLoadSideEconomizer,fileNamePrefix="Buildings_maint_8_0_x_Buildings_Applications_DataCenters_ChillerCooled_Examples_IntegratedPrimaryLoadSideEconomizer",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 2.452/2.452, allocations: 285.6 MB / 293.1 MB, free: 10.26 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.002276/0.002276, allocations: 184.8 kB / 361.4 MB, free: 6.859 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.242/2.242, allocations: 205.3 MB / 0.62 GB, free: 11.63 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008746/0.0008748, allocations: 86 kB / 0.733 GB, free: 44.17 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.581e-05/2.595e-05, allocations: 4 kB / 0.8518 GB, free: 2.629 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8365/0.8365, allocations: 115.3 MB / 0.9644 GB, free: 78.77 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 10.4/11.24, allocations: 2.546 GB / 3.51 GB, free: 264.1 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003715/11.24, allocations: 102.3 kB / 3.51 GB, free: 264.1 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumCW[2].pressure.V_flow={0.006940000000000001, 0.02082, 0.0347, 0.04164}. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumCW[1].pressure.V_flow={0.006940000000000001, 0.02082, 0.0347, 0.04164}. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumPri[2].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumPri[1].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Applications/DataCenters/ChillerCooled/Examples/BaseClasses/PartialDataCenter.mo:121:5-121:17:writable] Error: Type mismatch in binding hydraulicEfficiency = Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency({0}, {0.7}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[1] V_flow; Real(max = 1.0, quantity = "Efficiency", unit = "1", min = 0.0)[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency Integer[1] V_flow; Real[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimaryLoadSideEconomizer Notification: Performance of FrontEnd: time 7.019/18.26, allocations: 1.108 GB / 4.619 GB, free: 101.9 MB / 0.9636 GB