Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF,fileNamePrefix="Buildings_maint_7_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases9xx_Case900FF",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF,fileNamePrefix="Buildings_maint_7_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases9xx_Case900FF",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.448/1.448, allocations: 249.5 MB / 257 MB, free: 7.016 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001034/0.001034, allocations: 176.8 kB / 316.3 MB, free: 3.285 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.835/1.835, allocations: 205.3 MB / 0.5671 GB, free: 15.84 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009909/0.000991, allocations: 102.2 kB / 0.6714 GB, free: 4.949 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.376e-05/2.377e-05, allocations: 4 kB / 0.7815 GB, free: 102.6 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2658/0.2659, allocations: 106.3 MB / 0.8853 GB, free: 12.18 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.715/7.981, allocations: 2.361 GB / 3.246 GB, free: 215.8 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0005265/7.982, allocations: 114.9 kB / 3.247 GB, free: 215.8 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF Notification: Performance of FrontEnd: time 1.907/9.889, allocations: 0.5169 GB / 3.763 GB, free: 128.9 MB / 0.8698 GB