Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_HeatPumps_Validation_Carnot_TCon_etaPL",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_HeatPumps_Validation_Carnot_TCon_etaPL",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.44/1.44, allocations: 249.5 MB / 257 MB, free: 6.949 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001092/0.001092, allocations: 175.4 kB / 316.3 MB, free: 3.238 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.659/1.659, allocations: 205.3 MB / 0.5671 GB, free: 15.88 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001041/0.001041, allocations: 92.17 kB / 0.6714 GB, free: 4.992 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 1.715e-05/1.718e-05, allocations: 4 kB / 0.7815 GB, free: 102.6 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2248/0.2249, allocations: 106.3 MB / 0.8853 GB, free: 12.16 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.533/1.758, allocations: 415.2 MB / 1.291 GB, free: 324.2 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002515/1.758, allocations: 90.34 kB / 1.291 GB, free: 324.2 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/HeatPumps/Examples/Carnot_TCon.mo:17:3-31:71:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope Buildings.Fluid.HeatPumps.Carnot_TCon$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL Notification: Performance of FrontEnd: time 0.1486/1.906, allocations: 82.86 MB / 1.372 GB, free: 246.2 MB / 0.8698 GB