Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_OutputVariable_OneZoneOneOutputVariableSummer",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_OutputVariable_OneZoneOneOutputVariableSummer",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.475/2.475, allocations: 390.5 MB / 398 MB, free: 10.98 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001317/0.001317, allocations: 168.9 kB / 491.2 MB, free: 1.625 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.882/1.882, allocations: 221.5 MB / 0.7868 GB, free: 13.38 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001133/0.001133, allocations: 99.89 kB / 0.9269 GB, free: 13.88 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 2.304e-05/2.337e-05, allocations: 4 kB / 1.073 GB, free: 182 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3155/0.3156, allocations: 143 MB / 1.212 GB, free: 39.46 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.294/6.61, allocations: 1.96 GB / 3.172 GB, free: 366.6 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004568/6.611, allocations: 95.95 kB / 3.172 GB, free: 366.5 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/ThermalZones/EnergyPlus_9_6_0/BaseClasses/ThermalZoneAdapter.mo:101:3-131:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOneOutputVariableSummer Notification: Performance of FrontEnd: time 0.3347/6.945, allocations: 156.7 MB / 3.325 GB, free: 207.3 MB / 1.151 GB