Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneEnvironmentOutputVariable.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneEnvironmentOutputVariable,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_OutputVariable_OneEnvironmentOutputVariable",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneEnvironmentOutputVariable,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_OutputVariable_OneEnvironmentOutputVariable",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.481/2.481, allocations: 390.5 MB / 398 MB, free: 10.91 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001165/0.001164, allocations: 176.9 kB / 491.2 MB, free: 1.559 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.656/1.656, allocations: 221.5 MB / 0.7868 GB, free: 13.34 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008396/0.0008396, allocations: 102.3 kB / 0.9269 GB, free: 13.83 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 1.813e-05/1.815e-05, allocations: 0 / 1.073 GB, free: 182 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.378/0.378, allocations: 143 MB / 1.212 GB, free: 39.44 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.358/5.736, allocations: 1.733 GB / 2.946 GB, free: 130.8 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004271/5.736, allocations: 83.95 kB / 2.946 GB, free: 130.7 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/ThermalZones/EnergyPlus_9_6_0/OutputVariable.mo:39:3-71:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneEnvironmentOutputVariable Notification: Performance of FrontEnd: time 0.08195/5.818, allocations: 35.23 MB / 2.98 GB, free: 95.44 MB / 1.151 GB