Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_OnlyPartition",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition,fileNamePrefix="Buildings_latest_Buildings_ThermalZones_Detailed_Validation_TestConditionalConstructions_OnlyPartition",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.344/2.344, allocations: 390.5 MB / 398 MB, free: 10.95 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001536/0.001536, allocations: 184.2 kB / 491.2 MB, free: 1.578 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.713/1.713, allocations: 221.5 MB / 0.7868 GB, free: 13.25 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001219/0.001219, allocations: 98.28 kB / 0.9269 GB, free: 13.76 MB / 0.698 GB Notification: Performance of FrontEnd - loaded program: time 2.206e-05/2.234e-05, allocations: 4 kB / 1.073 GB, free: 181.9 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3142/0.3143, allocations: 143 MB / 1.212 GB, free: 39.43 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.85/7.164, allocations: 2.063 GB / 3.275 GB, free: 201.7 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003918/7.165, allocations: 98.06 kB / 3.275 GB, free: 201.7 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/ThermalZones/Detailed/BaseClasses/RoomHeatMassBalance.mo:246:11-246:38:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition Notification: Performance of FrontEnd: time 1.41/8.575, allocations: 237.2 MB / 3.507 GB, free: 292.5 MB / 1.151 GB