Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ZoneSurface.OneZoneControlledFloorTemperature.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ZoneSurface.OneZoneControlledFloorTemperature,fileNamePrefix="Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_ZoneSurface_OneZoneControlledFloorTemperature",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ZoneSurface.OneZoneControlledFloorTemperature,fileNamePrefix="Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_ZoneSurface_OneZoneControlledFloorTemperature",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.365/2.365, allocations: 387.4 MB / 394.9 MB, free: 13.35 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001714/0.001714, allocations: 180.8 kB / 487.4 MB, free: 5.027 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.643/1.643, allocations: 221.5 MB / 0.7824 GB, free: 0.9727 MB / 0.5417 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009919/0.0009921, allocations: 91.91 kB / 0.9219 GB, free: 2.219 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 2.16e-05/2.162e-05, allocations: 4 kB / 1.067 GB, free: 185.6 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.35/0.35, allocations: 142.4 MB / 1.206 GB, free: 43.85 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.379/6.729, allocations: 1.961 GB / 3.167 GB, free: 388.6 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002384/6.729, allocations: 97.05 kB / 3.167 GB, free: 388.5 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/ThermalZones/EnergyPlus_9_6_0/BaseClasses/ThermalZoneAdapter.mo:101:3-131:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ZoneSurface.OneZoneControlledFloorTemperature Notification: Performance of FrontEnd: time 0.2994/7.029, allocations: 156.7 MB / 3.32 GB, free: 229.3 MB / 1.151 GB