Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOutputVariable.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOutputVariable,fileNamePrefix="Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_OutputVariable_OneZoneOutputVariable",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOutputVariable,fileNamePrefix="Buildings_9_Buildings_ThermalZones_EnergyPlus_9_6_0_Validation_OutputVariable_OneZoneOutputVariable",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.42/2.42, allocations: 387.4 MB / 394.9 MB, free: 13.32 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001244/0.001244, allocations: 176.5 kB / 487.4 MB, free: 5.039 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.634/1.634, allocations: 221.5 MB / 0.7824 GB, free: 0.9414 MB / 0.5417 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009946/0.0009949, allocations: 99.8 kB / 0.9219 GB, free: 2.172 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 2.252e-05/2.254e-05, allocations: 0 / 1.067 GB, free: 185.6 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3333/0.3333, allocations: 142.4 MB / 1.206 GB, free: 43.84 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.312/5.645, allocations: 1.733 GB / 2.939 GB, free: 124.2 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004176/5.646, allocations: 88.62 kB / 2.939 GB, free: 124.1 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/ThermalZones/EnergyPlus_9_6_0/OutputVariable.mo:39:3-71:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.OutputVariable.OneZoneOutputVariable Notification: Performance of FrontEnd: time 0.08695/5.733, allocations: 36.16 MB / 2.974 GB, free: 94.02 MB / 1.151 GB