Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF,fileNamePrefix="Buildings_9_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case600FF",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF,fileNamePrefix="Buildings_9_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case600FF",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.373/2.373, allocations: 387.4 MB / 394.9 MB, free: 13.36 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001172/0.001172, allocations: 180.8 kB / 487.4 MB, free: 5.02 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.74/1.74, allocations: 221.5 MB / 0.7824 GB, free: 1.02 MB / 0.5417 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001151/0.001151, allocations: 98.64 kB / 0.9219 GB, free: 2.25 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 1.924e-05/1.908e-05, allocations: 0 / 1.067 GB, free: 185.6 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3337/0.3337, allocations: 142.4 MB / 1.206 GB, free: 43.88 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.185/6.519, allocations: 2.09 GB / 3.296 GB, free: 250.2 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003863/6.52, allocations: 118.6 kB / 3.296 GB, free: 250.1 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF Notification: Performance of FrontEnd: time 2.226/8.746, allocations: 0.6278 GB / 3.924 GB, free: 50.96 MB / 1.151 GB