Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels,fileNamePrefix="Buildings_9_Buildings_Electrical_AC_ThreePhasesBalanced_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels,fileNamePrefix="Buildings_9_Buildings_Electrical_AC_ThreePhasesBalanced_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.269/2.269, allocations: 387.4 MB / 394.9 MB, free: 13.37 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001109/0.001109, allocations: 172.9 kB / 487.4 MB, free: 5.039 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.541/1.541, allocations: 221.5 MB / 0.7824 GB, free: 0.957 MB / 0.5417 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009074/0.0009071, allocations: 97.41 kB / 0.9219 GB, free: 2.188 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 2.271e-05/2.274e-05, allocations: 4 kB / 1.067 GB, free: 185.6 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2982/0.2983, allocations: 142.4 MB / 1.206 GB, free: 43.83 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.475/4.773, allocations: 1.764 GB / 2.97 GB, free: 118.3 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003368/4.773, allocations: 103.9 kB / 2.97 GB, free: 118.2 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels Notification: Performance of FrontEnd: time 0.168/4.941, allocations: 72.54 MB / 3.041 GB, free: 45.42 MB / 1.151 GB