OMSimulator -r=Buildings_9_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctColdDuctMin.Subsequences.Validation.Alarms_res.mat --tempDir=temp_Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctColdDuctMin_Subsequences_Validation_Alarms_fmu --startTime=0 --stopTime=7200 --timeout=50 --tolerance=1e-06 Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctColdDuctMin_Subsequences_Validation_Alarms.fmu info: Set temp directory to "/tmp/omsimulator" info: Set working directory to "." info: New temp directory has been created: "temp_Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctColdDuctMin_Subsequences_Validation_Alarms_fmu" info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctColdDuctMin.Subsequences.Validation.Alarms/temp_Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctColdDuctMin_Subsequences_Validation_Alarms_fmu" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctColdDuctMin.Subsequences.Validation.Alarms" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctColdDuctMin.Subsequences.Validation.Alarms/temp_Buildings_9_Buildings_Controls_OBC_ASHRAE_G36_TerminalUnits_DualDuctColdDuctMin_Subsequences_Validation_Alarms_fmu/model-86w2l3cf" info: model doesn't contain any continuous state info: No result file will be created warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated at time 3750.000000 not ala.booToInt5.u assert | warning | Warning: the hot-duct damper is leaking. warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated at time 3750.000000 not ala.booToInt3.u assert | warning | Warning: the cold-duct damper is leaking. warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated at time 6279.545455 ala.assMes4.u assert | warning | Warning: hot-duct airflow sensor should be calibrated. warning: fmu (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Controls/OBC/CDL/Utilities/Assert.mo:11: The following assertion has been violated at time 6279.545455 ala.assMes2.u assert | warning | Warning: cold-duct airflow sensor should be calibrated. info: 4 warnings info: 0 errors