Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop,fileNamePrefix="Buildings_9_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_CoolingCoilHumidifyingHeating_ClosedLoop",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop,fileNamePrefix="Buildings_9_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_CoolingCoilHumidifyingHeating_ClosedLoop",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.469/2.469, allocations: 387.4 MB / 394.9 MB, free: 13.38 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001179/0.001179, allocations: 180.8 kB / 487.4 MB, free: 5.039 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.764/1.764, allocations: 221.5 MB / 0.7824 GB, free: 1.012 MB / 0.5417 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001037/0.001037, allocations: 103.8 kB / 0.9219 GB, free: 2.258 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 3.211e-05/3.225e-05, allocations: 4 kB / 1.067 GB, free: 185.6 MB / 0.7605 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3559/0.3559, allocations: 142.4 MB / 1.206 GB, free: 43.85 MB / 0.7605 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.896/7.252, allocations: 2.357 GB / 3.563 GB, free: 411.2 MB / 1.151 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004485/7.253, allocations: 107 kB / 3.563 GB, free: 411.2 MB / 1.151 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Applications/DataCenters/ChillerCooled/Equipment/Validation/CoolingCoilHumidifyingHeating_ClosedLoop.mo:9:22-9:46:writable] Error: Class Medium2 not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra.Medium. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Sensors/MassFractionTwoPort.mo:27:11-27:55:writable] Error: Variable Medium.substanceNames[1:Medium.nXi] not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Applications/DataCenters/ChillerCooled/Equipment/Validation/CoolingCoilHumidifyingHeating_ClosedLoop.mo:9:22-9:46:writable] Error: Class Medium2 not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra.Medium. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Fluid/Sensors/MassFractionTwoPort.mo:26:3-28:103:writable] Error: Class Medium.MassFraction not found in scope Buildings.Fluid.Sensors.MassFractionTwoPort$masFra while instantiating masFra.XiVec. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_ClosedLoop Notification: Performance of FrontEnd: time 0.7933/8.046, allocations: 380.3 MB / 3.935 GB, free: 44.68 MB / 1.151 GB