Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSpring.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSpring,fileNamePrefix="Buildings_8_Buildings_ThermalZones_EnergyPlus_Examples_SmallOffice_IdealHeatingCoolingSpring",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSpring,fileNamePrefix="Buildings_8_Buildings_ThermalZones_EnergyPlus_Examples_SmallOffice_IdealHeatingCoolingSpring",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.872/1.872, allocations: 289.9 MB / 297.4 MB, free: 6.473 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001873/0.001873, allocations: 188.9 kB / 366.7 MB, free: 1.688 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.256/2.256, allocations: 205.2 MB / 0.626 GB, free: 7.176 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008506/0.0008501, allocations: 87.86 kB / 0.74 GB, free: 39.57 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.672e-05/2.665e-05, allocations: 4 kB / 0.8598 GB, free: 12.97 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7897/0.7898, allocations: 116.3 MB / 0.9733 GB, free: 76.28 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.799/7.589, allocations: 2.132 GB / 3.106 GB, free: 340.9 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003643/7.589, allocations: 97.66 kB / 3.106 GB, free: 340.9 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSpring Notification: Performance of FrontEnd: time 7.376/14.97, allocations: 1.613 GB / 4.719 GB, free: 114.9 MB / 0.9792 GB