Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week,fileNamePrefix="Buildings_8_Buildings_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_Validation_FiniteDifference_1Week",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week,fileNamePrefix="Buildings_8_Buildings_Fluid_Geothermal_Borefields_BaseClasses_HeatTransfer_Validation_FiniteDifference_1Week",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.704/1.704, allocations: 289.9 MB / 297.4 MB, free: 6.34 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001342/0.001342, allocations: 188.8 kB / 366.7 MB, free: 1.668 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.652/1.652, allocations: 205.2 MB / 0.626 GB, free: 7.133 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008679/0.0008682, allocations: 88.3 kB / 0.74 GB, free: 39.53 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.136e-05/2.138e-05, allocations: 4 kB / 0.8598 GB, free: 12.92 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.7148/0.7149, allocations: 116.3 MB / 0.9734 GB, free: 76.24 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.242/0.957, allocations: 170.6 MB / 1.14 GB, free: 11.39 MB / 0.7448 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000301/0.9573, allocations: 103.9 kB / 1.14 GB, free: 11.29 MB / 0.7448 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Geothermal/Borefields/BaseClasses/HeatTransfer/GroundTemperatureResponse.mo:8:3-10:87:writable] Error: Array equation has unknown size in groTemRes.borFieDat.conDat.cooBor=borFieDat.conDat.cooBor. Error: Internal error - InstUtil.moveBindings: Mismatched number of equations and variables. Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.Validation.FiniteDifference_1Week Notification: Performance of FrontEnd: time 0.1577/1.115, allocations: 33.73 MB / 1.173 GB, free: 9.598 MB / 0.7761 GB