Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels,fileNamePrefix="Buildings_8_Buildings_Electrical_AC_OnePhase_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels,fileNamePrefix="Buildings_8_Buildings_Electrical_AC_OnePhase_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.7/1.7, allocations: 289.9 MB / 297.4 MB, free: 6.387 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0009844/0.0009844, allocations: 176.8 kB / 366.7 MB, free: 1.645 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.506/1.506, allocations: 205.3 MB / 0.626 GB, free: 7.16 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001021/0.001021, allocations: 93.73 kB / 0.74 GB, free: 39.54 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.734e-05/2.737e-05, allocations: 4 kB / 0.8598 GB, free: 12.95 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6881/0.6881, allocations: 116.3 MB / 0.9734 GB, free: 76.05 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.71/5.399, allocations: 2.103 GB / 3.076 GB, free: 3.48 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003149/5.399, allocations: 103.9 kB / 3.076 GB, free: 3.379 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.AC.OnePhase.Sources.Examples.PVPanels Notification: Performance of FrontEnd: time 0.6712/6.07, allocations: 64.07 MB / 3.139 GB, free: 326.7 MB / 0.948 GB