Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneOneYear.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneOneYear,fileNamePrefix="Buildings_8_0_0_Buildings_ThermalZones_EnergyPlus_Validation_ThermalZone_OneZoneOneYear",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneOneYear,fileNamePrefix="Buildings_8_0_0_Buildings_ThermalZones_EnergyPlus_Validation_ThermalZone_OneZoneOneYear",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.475/2.475, allocations: 284.9 MB / 292.4 MB, free: 10.57 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001483/0.001483, allocations: 188.8 kB / 360.6 MB, free: 7.273 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.16/2.16, allocations: 205.3 MB / 0.6191 GB, free: 12.2 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001157/0.001156, allocations: 102.5 kB / 0.7321 GB, free: 44.73 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.301e-05/2.298e-05, allocations: 4 kB / 0.8509 GB, free: 3.336 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.852/0.8521, allocations: 115.2 MB / 0.9634 GB, free: 78.51 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.018/6.871, allocations: 2.111 GB / 3.075 GB, free: 7.109 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003525/6.871, allocations: 91.02 kB / 3.075 GB, free: 7.066 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.OneZoneOneYear Notification: Performance of FrontEnd: time 1.214/8.085, allocations: 153.7 MB / 3.225 GB, free: 250 MB / 0.948 GB