Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneEnvironmentOutputVariable.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneEnvironmentOutputVariable,fileNamePrefix="Buildings_8_0_0_Buildings_ThermalZones_EnergyPlus_Validation_OutputVariable_OneEnvironmentOutputVariable",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneEnvironmentOutputVariable,fileNamePrefix="Buildings_8_0_0_Buildings_ThermalZones_EnergyPlus_Validation_OutputVariable_OneEnvironmentOutputVariable",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.422/2.422, allocations: 284.9 MB / 292.4 MB, free: 10.53 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001423/0.001423, allocations: 184.8 kB / 360.6 MB, free: 7.281 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.26/2.26, allocations: 205.3 MB / 0.6191 GB, free: 12.19 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001113/0.001112, allocations: 90.31 kB / 0.7321 GB, free: 44.71 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.226e-05/2.231e-05, allocations: 0 / 0.8508 GB, free: 3.316 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8383/0.8384, allocations: 115.3 MB / 0.9634 GB, free: 78.52 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.195/7.033, allocations: 2.074 GB / 3.037 GB, free: 44.9 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000354/7.034, allocations: 89.7 kB / 3.037 GB, free: 44.86 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/EnergyPlus/OutputVariable.mo:39:3-69:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.OutputVariable.OneEnvironmentOutputVariable Notification: Performance of FrontEnd: time 0.1364/7.17, allocations: 34.13 MB / 3.07 GB, free: 14.2 MB / 0.948 GB