Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.Detailed.Examples.FFD.WindowWithoutShade.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Examples.FFD.WindowWithoutShade,fileNamePrefix="Buildings_8_0_0_Buildings_ThermalZones_Detailed_Examples_FFD_WindowWithoutShade",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Examples.FFD.WindowWithoutShade,fileNamePrefix="Buildings_8_0_0_Buildings_ThermalZones_Detailed_Examples_FFD_WindowWithoutShade",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.406/2.406, allocations: 284.9 MB / 292.4 MB, free: 10.55 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001504/0.001503, allocations: 184.8 kB / 360.6 MB, free: 7.285 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.088/2.088, allocations: 205.3 MB / 0.6191 GB, free: 12.19 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001039/0.001039, allocations: 90.25 kB / 0.7321 GB, free: 44.73 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.45e-05/2.449e-05, allocations: 4 kB / 0.8509 GB, free: 3.34 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8155/0.8155, allocations: 115.3 MB / 0.9634 GB, free: 78.57 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.008/7.824, allocations: 2.211 GB / 3.175 GB, free: 258.8 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003051/7.824, allocations: 94.88 kB / 3.175 GB, free: 258.8 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/Detailed/BaseClasses/RoomHeatMassBalance.mo:151:11-151:27:writable] Error: Type mismatch in binding name = {"North Wall", "South Wall", "Floor", "Ceiling"}, expected subtype of String, got type String[4]. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Examples.FFD.WindowWithoutShade Notification: Performance of FrontEnd: time 2.742/10.57, allocations: 479.2 MB / 3.643 GB, free: 170.3 MB / 0.948 GB