Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature,fileNamePrefix="Buildings_8_0_0_Buildings_Fluid_HeatPumps_Validation_Carnot_TCon_LowTemperature",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature,fileNamePrefix="Buildings_8_0_0_Buildings_Fluid_HeatPumps_Validation_Carnot_TCon_LowTemperature",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.485/2.485, allocations: 284.9 MB / 292.4 MB, free: 10.6 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001487/0.001486, allocations: 180.9 kB / 360.6 MB, free: 7.305 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.102/2.102, allocations: 205.3 MB / 0.6191 GB, free: 12.22 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001034/0.001033, allocations: 96.58 kB / 0.7321 GB, free: 44.72 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.576e-05/2.574e-05, allocations: 4 kB / 0.8508 GB, free: 3.336 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8202/0.8202, allocations: 115.3 MB / 0.9634 GB, free: 78.71 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.307/2.127, allocations: 421.7 MB / 1.375 GB, free: 146.9 MB / 0.8542 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003081/2.128, allocations: 89.39 kB / 1.375 GB, free: 146.8 MB / 0.8542 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Fluid/HeatPumps/Examples/Carnot_TCon.mo:17:3-31:71:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope Buildings.Fluid.HeatPumps.Carnot_TCon$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature Notification: Performance of FrontEnd: time 0.271/2.399, allocations: 84.06 MB / 1.457 GB, free: 76.7 MB / 0.8542 GB