Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel,fileNamePrefix="Buildings_8_0_0_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_PumpParallel",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel,fileNamePrefix="Buildings_8_0_0_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_PumpParallel",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.55/2.55, allocations: 284.9 MB / 292.4 MB, free: 10.57 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001399/0.001399, allocations: 176.8 kB / 360.6 MB, free: 7.277 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.299/2.299, allocations: 205.3 MB / 0.6191 GB, free: 12.2 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001032/0.001031, allocations: 87.92 kB / 0.7321 GB, free: 44.74 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.442e-05/2.44e-05, allocations: 4 kB / 0.8509 GB, free: 3.328 MB / 0.5886 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.8279/0.828, allocations: 115.3 MB / 0.9634 GB, free: 78.55 MB / 0.6667 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.338/2.166, allocations: 447.7 MB / 1.401 GB, free: 121.4 MB / 0.8542 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003973/2.167, allocations: 107.9 kB / 1.401 GB, free: 121.3 MB / 0.8542 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/Applications/DataCenters/ChillerCooled/Equipment/BaseClasses/PartialPumpParallel.mo:101:11-101:18:writable] Error: Type mismatch in binding hydraulicEfficiency = Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency({0}, {0.7}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[1] V_flow; Real(max = 1.0, quantity = "Efficiency", unit = "1", min = 0.0)[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency Integer[1] V_flow; Real[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$pumPar1$per$hydraulicEfficiency;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.PumpParallel Notification: Performance of FrontEnd: time 2.177/4.343, allocations: 463.6 MB / 1.853 GB, free: 118.9 MB / 0.9323 GB