Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_Static.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_Static,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_HeatPumps_Validation_ScrollWaterToWater_Static",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.19/2.19, allocations: 248.7 MB / 256.2 MB, free: 7.027 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.0015/0.0015, allocations: 174 kB / 315.4 MB, free: 3.988 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.104/2.104, allocations: 205.3 MB / 0.5662 GB, free: 0.625 MB / 410.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001161/0.001161, allocations: 93.77 kB / 0.6704 GB, free: 5.84 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.569e-05/2.566e-05, allocations: 4 kB / 0.7803 GB, free: 103.3 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2201/0.2202, allocations: 106.3 MB / 0.8841 GB, free: 13 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.968/2.188, allocations: 415.5 MB / 1.29 GB, free: 261.1 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003586/2.189, allocations: 89.77 kB / 1.29 GB, free: 261.1 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Media/Refrigerants/R410A/specificIsobaricHeatCapacityVap_Tv.mo:42:3-42:35:writable] Error: Variable A not found in scope Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Media/Refrigerants/R410A/isentropicExponentVap_Tv.mo:20:3-20:84:writable] Error: Class Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv not found in scope Buildings.Fluid.HeatPumps.Compressors.ScrollCompressor$heaPum$com.ref.isentropicExponentVap_Tv (looking for a function or record). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_Static Notification: Performance of FrontEnd: time 0.3771/2.566, allocations: 117.7 MB / 1.405 GB, free: 195 MB / 0.8698 GB