Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LimitedCapacity.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LimitedCapacity,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_HeatPumps_Validation_Carnot_TCon_LimitedCapacity",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.363/2.363, allocations: 248.7 MB / 256.2 MB, free: 7.047 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00153/0.00153, allocations: 186.3 kB / 315.4 MB, free: 4.012 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.106/2.106, allocations: 205.3 MB / 0.5662 GB, free: 0.5625 MB / 410.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.00106/0.001059, allocations: 86.53 kB / 0.6704 GB, free: 5.762 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.346e-05/2.353e-05, allocations: 4 kB / 0.7803 GB, free: 103.3 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2047/0.2047, allocations: 106.3 MB / 0.8841 GB, free: 13.02 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.944/2.149, allocations: 415 MB / 1.289 GB, free: 261.8 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002943/2.149, allocations: 88.78 kB / 1.289 GB, free: 261.8 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/HeatPumps/Examples/Carnot_TCon.mo:17:3-31:71:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope Buildings.Fluid.HeatPumps.Carnot_TCon$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LimitedCapacity Notification: Performance of FrontEnd: time 0.3257/2.475, allocations: 82.65 MB / 1.37 GB, free: 231.3 MB / 0.8698 GB