Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.HeatExchangers.DXCoils.AirCooled.Validation.SingleSpeedEnergyPlus.conf.json Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.HeatExchangers.DXCoils.AirCooled.Validation.SingleSpeedEnergyPlus,fileNamePrefix="Buildings_7_0_0_Buildings_Fluid_HeatExchangers_DXCoils_AirCooled_Validation_SingleSpeedEnergyPlus",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.326/2.326, allocations: 248.7 MB / 256.2 MB, free: 7.07 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001534/0.001534, allocations: 182.9 kB / 315.4 MB, free: 4 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.052/2.052, allocations: 205.3 MB / 0.5662 GB, free: 0.5469 MB / 410.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001175/0.001175, allocations: 93.97 kB / 0.6704 GB, free: 5.746 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 2.686e-05/2.739e-05, allocations: 7.984 kB / 0.7804 GB, free: 103.3 MB / 0.5417 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2221/0.2221, allocations: 106.3 MB / 0.8841 GB, free: 12.96 MB / 0.5573 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.154/7.376, allocations: 2.248 GB / 3.132 GB, free: 104.9 MB / 0.8698 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000321/7.377, allocations: 102.7 kB / 3.132 GB, free: 104.8 MB / 0.8698 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/HeatExchangers/DXCoils/BaseClasses/PartialDXCoil.mo:69:3-70:71:writable] Error: Array dimension mismatch, expression {inStream(sinSpeDX.port_a.Xi_outflow[1])} has type Real[1], expected array dimensions [0]. Error: Error occurred while flattening model Buildings.Fluid.HeatExchangers.DXCoils.AirCooled.Validation.SingleSpeedEnergyPlus Notification: Performance of FrontEnd: time 3.563/10.94, allocations: 0.6663 GB / 3.798 GB, free: 98.68 MB / 0.8698 GB